Specifications : BKG-Type: 1000.15/50 and 750.15/50
Structure
Guide rail T 82 B
Galvanized self-supporting shaft structure
The shaft structure must be fastened to the floor, the ceiling cut-out and the ceiling.
Landing doors
Hinged double door at floor level, acc. to DIN 18090, galvanized sheet steel
Double machine room door, single-skin, with safety lock, galvanized sheet steel
Car
Car suspension 2 : 1
Roller type safety gear as protection against dropping
Capacity 1000kg
Suspension 2 x roller chain acc. to DIN 8787 12B-1
Car galvanized sheet steel
Car bottom galvanized sheet steel
Speed governor
Wooden buffer rails
Counterweight
Balance weight
Drive unit
Type FG with hand wheel
Structural shape B9
Speed = 0.15m/s
Chain wheel ø 151.0
Motor output = 3.00 kW
Motor idle-running revolutions = 1500 1/min
60 trips/h
Rated current 3 x 400V = 9.2A or Rated current 3 x 230V = 15.9A
Thermal motor protection and short circuit quick release
Starting current = 3 x rated current
Single-circuit brake 205V/DC
Electro-technics
Execution of the control board
Installation run
Lockable 3-pole main switch
Phase monitoring relay
Travel time control
Arrival signal, travel stop
Park landing (freely choosable)
Control voltage 24V/AC
Diagnostic system
Indications and operating elements at the landings
Position indicator, call accepted
In-use indicator, fault indicator
Call and send button, bell button |